Multi-functions: Battery inverter, AC charger, AC bypass and UPS
Three stage battery charging mode, compatible with Gel, AGM, Flooded, Lithium batteries
Built-in auto transfer switch between DC power and AC power
Reprogrammable Interactive Display Control System CR10 for easy data reading
Bypass mode increase the efficiency and make the quality of the AC output the same as AC input
This type of solar inverter with charger provides electronic protection against Over/under voltage, overload, over-current, overheating, short circuit
2 years warranty
Models | LPT4000 |
Output Power | 4000W |
Surge Power | 12000W |
Output Voltage | 100/110/120VAC±5%, 220/230/240VAC±3% |
Oput Frequency | 50/60Hz±0.5% |
Output Waveform | True Sine Wave(THD<5%) |
Power Factor | 0.1~1 |
DC Input Voltage | 24/48VDC |
Voltage Range | 20.0~31.0/42.0~62.0VDC |
Power Saving Mode | <20W |
Efficiency | 110VAC 86%; 230VAC 86% |
AC Charger | |
AC Input Voltage | 90~135VAC/190~245VAC |
DC Output Voltage | Fast(14.0~15.1V), Float(13.3V~13.8V), (*2 for 24VDC, *4 for 48VDC) |
Over Charge Protection | 15.7VDC(*2 for 24VDC, *4 for 48VDC) |
Charge Current | 110VAC 50A/30A; 220VAC 65A/35A |
AC Bypass | |
Transfer Time | <8 ms |
Input Volt. Waveform | Utility AC or Generator (Sine Wave) |
Max Bypass Current | 30A |
Control&Signal | |
LED Indicator | Working Mode |
LCD Screen | AC Input, AC Output, DC Input, Output Frequency, Load Percentage, Working Mode, Fault Indicator |
Remote Control(optional) | CR10~11 |
Battery Type | Manual Optional |
Safety&EMC | |
Safety | UL458, LVD (EN60950) |
EMC | FCC Part15 Class A, CE (EN55022:2006+A1:2007) |
Environment | |
Operating Temp | -20~50℃ |
Working Humidity | 20~90%RH |
Storage Temp | -30~70℃ |
Other Information | |
Cooling | Automatically controlled cooling fan |
Weight(kg) | 37 |
Size(mm) | 670*255*185 |
Application | Vehicle, Yacht, Solar power systems, Portable equipment, Power tools, Home and office appliances |