6000W pure sine wave
This kind of split phase inverter charger is equipped with RS485 communication modules
Low THD ensure sensitive loads working stably
MAX. 60A charge current compatible with AGM/GEL/Flooded/Lithium batteries
Heavy duty design for motor loads
High working temperature tolerance for -10~50℃ at 100% continuous output
Battery temperature compensation for energizing battery in cold environment
Ultra-low idle consumption could effectively save the energy
Auto GEN start/stop
2 years warranty
Models | DPT6000 |
Rated Power(-10-50℃) | 6000W |
DC Input | |
Rated Voltage | 24VDC (20.0~32.0VDC)x2 for 48VDC |
Max. Charge Current | 75A-house battery |
Battery Type | AGM/Gel/Flooded/Lithium |
AC Input | |
Output Voltage | 170-275VAC |
Input Frequency | 45~65Hz |
AC Output | |
Output Voltage | 120/240VAC±5% |
Oput Frequency | 50/60Hz±0.3 |
Wave Form | Pure Sine Wave |
Transfer Time | ≤8ms |
Efficiency | >88% |
Overload | 105-120% 10s/ >120% 3s/ >150% 1s |
Max. Bypass | 7200W |
Protection | DC over/low volt, AC input low/low volt, AC short circuit, over temp, overload |
Self-consumption | 50.0W |
Idle-consumption | 23.5W |
Protection | |
DC Low-volt Alarm/Shutdown | 21.0V (Customizable at Engineering mode); x2 for 48VDC |
AC Low-volt Switch To DC | 187.0V (Customizable at Engineering mode) |
Bypass To Invertering | 198.0V (Customizable at Engineering mode) |
Battery Over-charge Shutdown | 31.4V |
General | |
Working Temperature | -10~45℃ |
Storage Temperature | -20~55℃ |
Work/ Storage Humidity | 0-90% No condensation |
Dimension (W*D*H) | 607*308*198mm |